 - Product Name:FDL16-32 10kA
- Keyword:
 
- Be viewed: 9560 Times
  Product introduction
  
      
      FDL16-32
	 
 
Technical Data FDL16-32
	
		
Construction and Feature
◆Provides protection against earth fault/leakage current and function
of isolation
◆Provides protection against over-voltage
◆Applicable to terminal and pin/fork type busbar connection
◆Contact position indication
◆Fire resistant plastic parts endures abnormal heating and strong
impact
◆ Automatically disconnect the circuit when earth fault/leakage
current occurs and exceeds the rated sensitivity.
◆ Independent of power supply and line voltage and free from
external interference, voltage fluctuation.
Overall:installation dimensions
						
							 
 
						   
      
  
 
Technical Data FDL16-32
| Standards | AS/NZS 61009 - 1 | 
| Magnetic tripping characteristics | B,C, D | 
| Residual tripping characteristics | AC | 
| Rated current(A) | 6,10,16,20,25,32 | 
| Rated residual current(mA) | 30, 100,300 | 
| Calibration temperature | 30℃ | 
| Rated voltage 1P | 240V | 
| Frequency | 50/60 | 
| Maximum service voltage | 264 | 
| Tripping duration: | Instaneous<0.1s | 
| Power supply | Line & Load | 
| Selectivity class | 3 | 
| Residual making and breaking capacity | 2000A | 
| Short circuit capacity | 10000A | 
| Isolation application (IEC 60947-2) | Yes | 
| Insulation resistance (Mohm) | 1,000 | 
| Insulation voltage (V) | 500 | 
| Dielectric rigidity (V) | 2,500 | 
| Vibration resistance | 1.5g | 
| Endurance (operations) electrical | >4,000 | 
| mechanical | >20,000 | 
| Protection degree outside | IP20 | 
| inside enclosure | IP40 | 
| Self extinguishing degree (UL 94) | V2 | 
| Tropicalisation (IEC 60068-2) | +55℃/95% RH | 
| Operating temperature | -5/+55℃ | 
| Storage temperature | -25/+70℃ | 
| Terminal capacity (top & bottom) min / max | 1-16mm | 
| Terminal torque (top / bottom) | 3 | 
| Busbar systems | Yes | 
| Accessories | No | 
| Dimensions (mm) | 72(H)81(L)18(W) | 
| Weight (g) | 105 | 
Construction and Feature
◆Provides protection against earth fault/leakage current and function
of isolation
◆Provides protection against over-voltage
◆Applicable to terminal and pin/fork type busbar connection
◆Contact position indication
◆Fire resistant plastic parts endures abnormal heating and strong
impact
◆ Automatically disconnect the circuit when earth fault/leakage
current occurs and exceeds the rated sensitivity.
◆ Independent of power supply and line voltage and free from
external interference, voltage fluctuation.
Overall:installation dimensions
 
 
						
 
 
 